Home / John Deere / 4710

John Deere 4710

200245 HPStandard DieselT1a
A+
Excellent
Score: 95.0/100
Recalls
322
Found
Known Issues
5
See details
Auction Records
0
No price data
Reliability
A+
95/100

Specifications

Engine Power45 HP
Engine (kW)33 kW
Fuel TypeStandard Diesel
CategoryT1a
Production Years2002–2002
Variants2 found

Safety Recalls

322 found
Safety recall — John Deere JD-8R370 (Japanese market, reference 1241810)

Japanese manufacturer safety recall affecting the lighting. Declared production window: 2021–2022.

LightingJP
On certain side-by-side UTVs, the owner's manual is missing information for how a person can contact Transport Canada to report a safety concern.

On certain side-by-side UTVs, the owner's manual is missing information for how a person can contact Transport Canada to report a safety concern. Canadian regulations require all companies to provide this information in the owner's manual.

OtherCA
On certain side-by-side UTVs, the owner's manual is missing information for how a person can contact Transport Canada to report a safety concern.

On certain side-by-side UTVs, the owner's manual is missing information for how a person can contact Transport Canada to report a safety concern. Canadian regulations require all companies to provide this information in the owner's manual.

OtherCA
On certain side-by-side UTVs, the owner's manual is missing information for how a person can contact Transport Canada to report a safety concern.

On certain side-by-side UTVs, the owner's manual is missing information for how a person can contact Transport Canada to report a safety concern. Canadian regulations require all companies to provide this information in the owner's manual.

OtherCA
Safety recall — John Deere JD-7R310 (Japanese market, reference 1241260)

Japanese manufacturer safety recall affecting the electronic control. Declared production window: 2020–2024.

Electronic controlJP
+317 more recalls
Unlock with full report

Known Issues

5 reported
5 low
Finding manuals online?
low

We have a JD4710 sprayer go down and I’m trying to find manuals so we can repair it. After searching through a bunch of questionable websites, I found one that seemed to be ok. I made and account and downloaded the manual (TM1861), but the link they provided was just a zip file that goes to nowhere. Are there any reputable sources to find these manuals? Should I call my credit card company and charge back from this website?

General
Drain valve location.
low

Does anyone know where the engine block coolant drain valve is on a john deere 4710 tractor is located?

Engine
Jd 4710 tractor
low

Headed to look at a 4710 with loader, tractor looks immaculate from the pictures I’ve seen. Power reverser 4wd with 2400 hours. Only issue seller is stating is fuel guage doesn’t work. Asking price is $19,000 firm. Any advice on what to look for or check when I go to check it out? Thanks for any advice

Hydraulics
Warm up in cold temps
low

Just wondering what everyone’s procedure is for warm up in cold weather. First snow of year that needed plowing here in Pa and temps single digits. Running jd 4710 with loader. Engine fires easily without running glow plugs and temp gauge is off the needle in 10 mins but what’s the best way to heat up the hydro oil. Pwr reverser btw. Thanks all

Engine
Using a vacuum planter with open center hydraulics
low

So in trying to use a MF4710 tractor that has open center hydraulics with a JD 7300 max emerge 2 vacuum planter. I've been reading a lot of info and kinda confused but I think I understand the general idea being that a bypass/modification of the hydraulic plumbing is needed as to not overwork the tractor's hydraulic pump due to not being able to control the flow to and from the pump and planter. Bypass line: bypass the tractor's hydraulic pump on the return line (rather than through the traditional port with the quick connection) directly into the reservoir via either the fill hole or a level check plug. Power beyond adapter or T connection to connect the supply and return lines: use pool This is to prevent an abrupt change in the oil pressure entering and leaving the pump when the vacuum part of the planter is shut off Is there anything wrong or that needs to be addressed in my understanding?

Hydraulics

Market Value

No auction data available for this model.

Hours Benchmark

Class: Utility (40100 HP)
Low use300 /year
Typical500 /year
High use750 /year
Typical lifetime10,000 hours
Expected life15 years

Have a specific John Deere 4710 VIN to check?

Model data shows the average — a VIN/PIN lookup pulls the per-unit history (theft, recalls, prior owners, hours).

Found on the chassis plate or registration papers

Unlock Full John Deere 4710 Report

Get the complete breakdown: pre-buy checklist, component reliability,322 recalls, 5 known issues, comparable sales, and theft risk analysis.

Full refund within 14 days · Stripe-secured payment

One-time payment · Instant access · Secure checkout